	    <title>Power Plant Control and Instrumentation - The Control of Boilers and HRSG Systems_Chapter-01</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056634"/>
		<id>tag:blog.daum.net,2009:kc445.12056634</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-09-24T00:34:22Z</updated>
	    <published>2009-09-24T00:34:22Z</published>
	    <content type="html">
	    	&lt;P&gt;Power Plant Control and Instrumentation - The Control of Boilers and HRSG Systems_Chapter-01&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;a title=&quot;http://cfile292.uf.daum.net/attach/1522791A4ABA3FF06C67E2&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot; border=&quot;0&quot; alt=&quot;첨부파일&quot; class=&quot;vam&quot;/&gt; 14005020-Power-Plant-Control-and-Instrumentation-The-Contro.pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Various Components of Thermal Power Plant</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056633"/>
		<id>tag:blog.daum.net,2009:kc445.12056633</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-09-24T00:28:18Z</updated>
	    <published>2009-09-24T00:28:18Z</published>
	    <content type="html">
	    	&lt;H1 class=title id=&quot;&quot;&gt;Various Components of Thermal Power Plant&lt;/H1&gt;
&lt;P class=title&gt;&amp;nbsp;&lt;/P&gt;
&lt;P class=title&gt;&amp;nbsp;&lt;/P&gt;
&lt;P class=&quot;title&quot;&gt;&lt;a title=&quot;http://cfile295.uf.daum.net/attach/1432761A4ABA3E7C304F32&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot; border=&quot;0&quot; alt=&quot;첨부파일&quot; class=&quot;vam&quot;/&gt; 18432951-Various-Components-of-Thermal-Power-Plant.pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Pipe-Fittings-and-Piping-Auxiliaries</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056627"/>
		<id>tag:blog.daum.net,2009:kc445.12056627</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-09-16T11:45:14Z</updated>
	    <published>2009-09-16T11:45:14Z</published>
	    <content type="html">
	    	&lt;P class=desc&gt;Pipe, Fittings, and Piping Auxiliaries / Page 1 / COURSE OBJECTIVES / COURSE TERMINAL OBJECTIVE Given &lt;/P&gt;
&lt;P class=&quot;desc&quot;&gt;&lt;a title=&quot;http://cfile255.uf.daum.net/attach/16760A1F4AB05123313ED8&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot; border=&quot;0&quot; alt=&quot;첨부파일&quot; class=&quot;vam&quot;/&gt; 19591272-Pipe-Fittings-and-Piping-Auxiliaries.pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Q1-3(이명용) KEPIC 심사 부적합사항 유형분석).pdf</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056626"/>
		<id>tag:blog.daum.net,2009:kc445.12056626</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-09-05T11:45:29Z</updated>
	    <published>2009-09-05T11:45:29Z</published>
	    <content type="html">
	    	&lt;P&gt;Kepic 심사반장님이 발표하신 자료입니다.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Q1-3(이명용) KEPIC 심사 부적합사항 유형분석).pdf&lt;/P&gt;
&lt;P&gt;&lt;a title=&quot;http://cfile262.uf.daum.net/attach/122D0F0C4AA1D0B33739EC&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot; border=&quot;0&quot; alt=&quot;첨부파일&quot; class=&quot;vam&quot;/&gt; Q1-3(이명용) KEPIC 심사 부적합사항 유형분석).pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Pressurized Water Reactor - 1600 MWe (EPR)</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056625"/>
		<id>tag:blog.daum.net,2009:kc445.12056625</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-08-20T10:46:50Z</updated>
	    <published>2009-08-20T10:46:50Z</published>
	    <content type="html">
	    	&lt;P&gt;Information on Finnish nuclear power plant Olkiluoto 3 which is scheduled to start operation in 2009 &lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://cfile202.uf.daum.net/attach/181129194A8CAB022CF709&quot; target=&quot;_blank&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot;/&gt; EPRallemand_26p[2].pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Proposed New Nuclear Power Plants</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056624"/>
		<id>tag:blog.daum.net,2009:kc445.12056624</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-08-20T10:45:23Z</updated>
	    <published>2009-08-20T10:45:23Z</published>
	    <content type="html">
	    	&lt;P&gt;Proposed New Nuclear Power Plants details the proposed plant location, design type, application date to the NRC, and the company that has submitted the application.&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://cfile225.uf.daum.net/attach/1410B7154A8CAAAD3E8723&quot; target=&quot;_blank&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot;/&gt; new-nuclear-plants_R8.pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Pressurized-Water Reactor and Reactor Vessel      </title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056623"/>
		<id>tag:blog.daum.net,2009:kc445.12056623</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-05-30T13:30:23Z</updated>
	    <published>2009-05-30T13:30:23Z</published>
	    <content type="html">
	    	&lt;P&gt;
&lt;TABLE cellSpacing=0 cellPadding=2 width=&quot;98%&quot; border=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=3 height=31&gt;&lt;B class=Pagetitle&gt;Pressurized-Water Reactor and Reactor Vessel&lt;/B&gt; &amp;nbsp; &lt;SPAN class=headrow1&gt;&lt;/SPAN&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; 
&lt;HR color=#cc3333 noShade SIZE=1&gt;
&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=2&gt;&lt;!-- height=&quot;3635&quot;---&gt;
&lt;TABLE width=&quot;70%&quot; align=center border=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD class=tabletitle&gt;Pressurized-Water Reactor (PWR)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD class=bodypara&gt;In a typical commercial pressurized light-water reactor (1) the reactor core generates heat, (2) pressurized-water in the primary coolant loop carries the heat to the steam generator, (3) inside the steam generator heat from the primary coolant loop vaporizes the water in a secondary loop producing steam, (4) the steam line directs the steam to the main turbine causing it to turn the turbine generator, which produces electricity. The unused steam is exhausted to the condenser where it is condensed into water. The resulting water is pumped out of the condenser with a series of pumps, reheated, and pumped back to the steam generator. The reactors core contains fuel assemblies which are cooled by water, which is force-circulated by electrically powered pumps. Emergency cooling water is supplied by other pumps, which can be powered by onsite diesel generators. Other safety systems, such as the containment cooling system, also need power.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG height=319 alt=&quot;Pressurized-Water Reactor&quot; src=&quot;http://eia.doe.gov/cneaf/nuclear/page/nuc_reactors/pwr.jpg&quot; width=405 border=0&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=46&gt;
&lt;P class=footnotes&gt;&lt;STRONG&gt;Sources:&lt;/STRONG&gt; &lt;A title=&quot;This will take you to another site. You are leaving EIA's website.&quot; href=&quot;http://www.nrc.gov/&quot; target=_blank&gt;&lt;U&gt;&lt;FONT color=#0000ff&gt;U.S. Nuclear Regulatory Commission&lt;/FONT&gt;&lt;/U&gt;&lt;/A&gt; &lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE width=&quot;70%&quot; align=center border=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD class=tabletitle&gt;Reactor Vessel&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG src=&quot;http://eia.doe.gov/cneaf/nuclear/page/nuc_reactors/reactorvessel.gif&quot;&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Boiling Water Reactor     </title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056622"/>
		<id>tag:blog.daum.net,2009:kc445.12056622</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-05-30T13:29:29Z</updated>
	    <published>2009-05-30T13:29:29Z</published>
	    <content type="html">
	    	&lt;P&gt;
&lt;TABLE cellSpacing=0 cellPadding=2 width=&quot;98%&quot; border=0&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=3 height=31&gt;&lt;B class=Pagetitle&gt;Boiling Water Reactor&lt;/B&gt; &amp;nbsp; &lt;SPAN class=headrow1&gt;&lt;/SPAN&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; 
&lt;HR color=#cc3333 noShade SIZE=1&gt;
&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top colSpan=2&gt;&lt;!-- height=&quot;3635&quot;---&gt;
&lt;TABLE width=&quot;70%&quot; align=center border=0&gt;&lt;!--  &lt;tr&gt;
 &lt;td class=&quot;tabletitle&quot;&gt;Boiling Water Reactor (BWR)&lt;/td&gt;
 &lt;/tr&gt;
 &lt;tr&gt;
 --&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD class=bodypara&gt;In a typical commercial boiling water reactor (1) the reactor core creates heat, (2) a steam-water mixture is produced when very pure water (reactor coolant) moves upward through the core absorbing heat, (3) the steam-water mixture leaves the top of the core and enters the two stages of moisture separation where water droplets are removed before the steam is allowed to enter the steam line, (4) the steam line directs the steam to the main turbine causing it to turn the turbine generator, which produces electricity. The unused steam is exhausted to the condenser where it is condensed into water. The resulting water is pumped out of the condenser with a series of pumps, reheated, and pumped back to the reactor vessel. The reactor's core contains fuel assemblies which are cooled by water, which is force-circulated by electrically powered pumps. Emergency cooling water is supplied by other pumps which can be powered by onsite diesel generators. Other safety systems, such as the containment cooling system, also need electric power.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;IMG alt=&quot;Boiling Water Reactor&quot; src=&quot;http://eia.doe.gov/cneaf/nuclear/page/nuc_reactors/bwr.gif&quot; border=0&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>FEM Analysis Procedures for Pressure Vessel Equipment</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056621"/>
		<id>tag:blog.daum.net,2009:kc445.12056621</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-04-18T13:30:05Z</updated>
	    <published>2009-04-18T13:30:05Z</published>
	    <content type="html">
	    	&lt;P&gt;FEM Analysis Procedures for Pressure Vessel Equipment&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://cfile204.uf.daum.net/attach/114A381049E957416367F6&quot; target=&quot;_blank&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot;/&gt; FEM Analysis Procedures for Pressure Vessel Equipments.pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Nuclear Reactor Types</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056620"/>
		<id>tag:blog.daum.net,2009:kc445.12056620</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-04-18T13:16:12Z</updated>
	    <published>2009-04-18T13:16:12Z</published>
	    <content type="html">
	    	&lt;P&gt;Many different reactor systems have been proposed and some of these have been developed to prototype and commercial scale. Six types of reactor (Magnox, AGR, PWR, BWR, CANDU and RBMK) have emerged as the designs used to produce commercial electricity around the world. A further reactor type, the so-called fast reactor, has been developed to full-scale demonstration stage. These various reactor types will now be described, together with current developments and some prototype designs. &lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://cfile219.uf.daum.net/attach/1860741149E95405A66DA6&quot; target=&quot;_blank&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot;/&gt; nuclear_reactor_types_UK[1].pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>KEPIC 인증심사에서 기술적 요구사항 달성방안</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056619"/>
		<id>tag:blog.daum.net,2009:kc445.12056619</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-04-16T20:40:14Z</updated>
	    <published>2009-04-16T20:40:14Z</published>
	    <content type="html">
	    	&lt;P&gt;KEPIC WEEK 2008 발표 자료&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;KIMS 박반욱 박사님 발표 자료입니다.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://cfile238.uf.daum.net/attach/175BDB0B49E719171C6E72&quot; target=&quot;_blank&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot;/&gt; Q3-2.pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>압력 용기 재료 충격시험 여부 결정 과정</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056618"/>
		<id>tag:blog.daum.net,2009:kc445.12056618</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-04-16T20:38:08Z</updated>
	    <published>2009-04-16T20:38:08Z</published>
	    <content type="html">
	    	&lt;P&gt;2008 KEPIC WEEK 발표 자료&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;압력 용기 재료 충격시험 여부 결정 과정&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://cfile220.uf.daum.net/attach/195D680B49E71866A4E437&quot; target=&quot;_blank&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot;/&gt; Q2-4.pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>KEPIC 인증 심사 착안 사항 및 개선 방안 : 기계 분야</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056617"/>
		<id>tag:blog.daum.net,2009:kc445.12056617</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-04-16T20:35:20Z</updated>
	    <published>2009-04-16T20:35:20Z</published>
	    <content type="html">
	    	&lt;P&gt;KEPIC 인증 심사 착안 사항 및 개선 방안 : 기계 분야&lt;/P&gt;
&lt;P&gt;2008 KEPIC WEEK&lt;/P&gt;
&lt;P&gt;KEPIC 선임 심사원 : 정삼술 의원님의 프리젠테이션 자료입니다.&lt;/P&gt;
&lt;P&gt;KEPIC 심사 준비시 도움이 되겠군요.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;http://cfile205.uf.daum.net/attach/135E140B49E717E7C98DE5&quot; target=&quot;_blank&quot;&gt;&lt;img src=&quot;http://icon.daum-img.net/editor/p_pdf_s.gif&quot;/&gt; Q1-3.pdf&lt;/a&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Coal-Fired Power Plants in South Korea</title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056616"/>
		<id>tag:blog.daum.net,2009:kc445.12056616</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-01-30T16:11:53Z</updated>
	    <published>2009-01-30T16:11:53Z</published>
	    <content type="html">
	    	&lt;P align=center&gt;&lt;FONT face=&quot;Rockwell Extra Bold&quot; color=#4b3838 size=6&gt;Coal-Fired Power Plants in South Korea&lt;/FONT&gt;&lt;/FONT&gt;&lt;BR&gt;
&lt;TABLE style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double; BORDER-COLLAPSE: collapse&quot; borderColor=#996600 height=640 cellSpacing=0 width=&quot;100%&quot; border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=1&gt;
&lt;P align=center&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/gumi.jpg&quot; width=300 border=1&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=1&gt;
&lt;P align=center&gt;&lt;IMG height=214 src=&quot;http://www.industcards.com/hadong.jpg&quot; width=300 border=1&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;34%&quot; height=1&gt;
&lt;P align=center&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/poryong-r.jpg&quot; width=300 border=1&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=37&gt;
&lt;P align=center&gt;&lt;B&gt;&lt;FONT face=Arial size=2&gt;Gumi&lt;/FONT&gt;&lt;/B&gt;&lt;FONT face=Arial size=2&gt;&lt;BR&gt;Location: Gyeongsangbuk-do&lt;BR&gt;Operator: STX Energy&lt;BR&gt;Configuration: 1 X 85 MW CHP&lt;BR&gt;Fuel: bituminous coal, oil&lt;BR&gt;Operation: 1992&lt;BR&gt;Boiler supplier: Hanjung&lt;BR&gt;T/G supplier: Hanjung&lt;BR&gt;EPC: Samwhan&lt;BR&gt;Quick facts: The Gumi plant was licensed in Jan 1987 and construction started a year later.&lt;/FONT&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Samwhan Corp&lt;BR&gt;Posted 29 Jan 2005&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=37&gt;
&lt;P align=center&gt;&lt;B&gt;&lt;FONT face=Arial size=2&gt;Hadong&lt;/FONT&gt;&lt;/B&gt;&lt;FONT face=Arial size=2&gt;&lt;BR&gt;Location: Gyeongsangnam-do&lt;BR&gt;Operator: Korea Southern Power Co&lt;BR&gt;Configuration: 6 X 500 MW&lt;BR&gt;Fuel: bituminous coal&lt;BR&gt;Operation: 1997-2001&lt;BR&gt;Boiler supplier: ABB, Doosan&lt;BR&gt;T/G supplier: Doosan&lt;BR&gt;Quick facts: This $4bn plant is fueled by imported bituminous coal and equipped with FGD scrubbers and other advanced air pollution control equipment. The units are constructed to the Korea Standard Coal Power Plant design with supercritical boilers. Doosan is building two additional 500-MW units.&lt;/FONT&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Korea Electric Power Co&lt;BR&gt;Posted 17 Mar 2001&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;34%&quot; height=37&gt;
&lt;P align=center&gt;&lt;FONT face=Arial size=2&gt;&lt;B&gt;Poryong&lt;/B&gt;&lt;BR&gt;Location: Chungcheongnam-do&lt;BR&gt;Operator: Korean Midland Power Co&lt;BR&gt;Configuration: 8 X 500 MW&lt;BR&gt;Fuel: bituminous coal&lt;BR&gt;Operation: 1983-2008&lt;BR&gt;Boiler supplier: B&amp;W, CE, Doosan&lt;BR&gt;T/G supplier: Toshiba, GE, Doosan&lt;BR&gt;Quick facts: &amp;nbsp;Units&amp;nbsp;3-6 were the first of Korea's&amp;nbsp;standardized 500-MW supercritical coal-fired units. MHI retrofit FGD scrubbers on Units 3-6 in the late 1990s.&lt;/FONT&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Korea Electric Power Co&lt;BR&gt;Re-posted 22 Oct 2008&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;34%&quot; height=226&gt;
&lt;P align=center&gt;&amp;nbsp;&lt;IMG height=219 src=&quot;http://www.industcards.com/tonghae.jpg&quot; width=300 border=1&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=226&gt;
&lt;P align=center&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/yongdong.jpg&quot; width=300 border=1&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=226&gt;
&lt;P align=center&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/yonghundo-kopec.jpg&quot; width=300 border=1&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;34%&quot; height=138&gt;
&lt;P align=center&gt;&lt;B&gt;&lt;FONT face=Arial size=2&gt;Tonghae&lt;/FONT&gt;&lt;/B&gt;&lt;FONT face=Arial size=2&gt;&lt;BR&gt;Location: Gangwon-do&lt;BR&gt;Operator: Korean East-West Power Co&lt;BR&gt;Configuration: 2 X 220 MW&lt;BR&gt;Fuel: anthracite coal&lt;BR&gt;Operation: 1998-1999&lt;BR&gt;Boiler supplier: ABB&lt;BR&gt;T/G supplier: Doosan&lt;BR&gt;EPC: Black &amp; Veatch, Kopec, Hanjung&lt;BR&gt;Quick facts: The plant has two 220-MW units with ACFB boilers designed for local anthracite, the largest such units in the country. Construction started in early 1993 and Unit-1 went commercial in Oct 1998. Fuel burn is about 1.2mn tpy.&lt;/FONT&gt; 
&lt;P align=center&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Korea Electric Power Co&lt;BR&gt;Posted 4 May 2002&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=138&gt;
&lt;P align=center&gt;&lt;B&gt;&lt;FONT face=Arial size=2&gt;Yongdong&lt;/FONT&gt;&lt;/B&gt;&lt;FONT face=Arial size=2&gt;&lt;BR&gt;Location: Gangwon-do&lt;BR&gt;Operator: Korean South-East Power Co&lt;BR&gt;Configuration: 1 X 125 MW, 1 X 200 MW&lt;BR&gt;Fuel: anthracite coal&lt;BR&gt;Operation: 1973-1979&lt;BR&gt;Boiler supplier: Babcock-Hitachi&lt;BR&gt;T/G supplier: Hitachi&lt;/FONT&gt; 
&lt;P align=center&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Korea South-East Power Co&lt;BR&gt;Posted 30 Jul 2004&lt;/FONT&gt; 
&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=138&gt;
&lt;P align=center&gt;&lt;B&gt;&lt;FONT face=Arial size=2&gt;Yonghungdo&lt;/FONT&gt;&lt;/B&gt;&lt;FONT face=Arial size=2&gt;&lt;BR&gt;Location: Incheon-gwangyoksi&lt;BR&gt;Operator: Korean South-East Power Co&lt;BR&gt;Configuration: 2 X 800 MW&lt;BR&gt;Fuel: bituminous coal&lt;BR&gt;Operation: 2004&lt;BR&gt;Boiler supplier: Alstom, Doosan&lt;BR&gt;T/G supplier: GE, Doosan&lt;BR&gt;EPC: Korea Power Engineering, Hyundai, Doosan, DongAh&lt;BR&gt;Quick facts: The supercritical plant has ESPs, a wet limestone FGD, and SCR. It cost $850/kW making it the least-cost coal-fired plant in the country. The integrated control system is based on the Emerson Process Management open-architecture Ovation software.&amp;nbsp; As the country's most modern coal-fired plant, Yonghungdo was named a 2005 Top Plant by Power magazine. Two 870-MW units are under construction at the site.&lt;/FONT&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Korea Power Engineering Co&lt;BR&gt;Posted 6 Feb 2005&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;34%&quot; height=138&gt;
&lt;P align=center&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=138&gt;
&lt;P align=center&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/yosu.jpg&quot; width=300 border=1&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=138&gt;
&lt;P align=center&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;34%&quot; height=138&gt;&amp;nbsp;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=138&gt;
&lt;P align=center&gt;&lt;B&gt;&lt;FONT face=Arial size=2&gt;Yosu&lt;/FONT&gt;&lt;/B&gt;&lt;FONT face=Arial size=2&gt;&lt;BR&gt;Location: Chollanam-do&lt;BR&gt;Operator: Korean South-East Power Co&lt;BR&gt;Configuration: 1 X 200 MW, 1 X 330 MW&lt;BR&gt;Fuel: bituminous coal, oil&lt;BR&gt;Operation: 1975-1977&lt;BR&gt;Boiler supplier: Stein, Babcock Power&lt;BR&gt;T/G supplier: Tosi, Marelli, MHI&lt;/FONT&gt; 
&lt;P align=center&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Korea South-East Power Co&lt;BR&gt;Posted 30 Jul 2004&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;33%&quot; height=138&gt;&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD style=&quot;BORDER-RIGHT: #4b3838 3px double; BORDER-TOP: #4b3838 3px double; BORDER-LEFT: #4b3838 3px double; BORDER-BOTTOM: #4b3838 3px double&quot; width=&quot;100%&quot; colSpan=3 height=45&gt;
&lt;P align=center&gt;&lt;IMG height=100 src=&quot;http://www.industcards.com/KOREA-S.jpg&quot; width=150 border=1&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Abbreviations: ABB = Asea Brown Boveri, ACFB = atmospheric fluidized bed,&amp;nbsp; B&amp;W = Babcock &amp; Wilcox, CE = Combustion Engineering, CHP = combined heat and power, GE = General Electric, Kopec = Korea Power Engineering Co, LG E&amp;C = LG Engineering &amp; Construction, MHI = Mitsubishi Heavy Industries, T/G = turbine generator, tpy = tons per year&lt;/FONT&gt;&lt;/P&gt;
	    </content>
	    	</entry>
    	<entry>
	    <title>Gas Turbine and Combined-Cycle Power Plants in South Korea </title>
		<link rel="alternate" type="text/html" href="http://blog.daum.net/kc445/12056615"/>
		<id>tag:blog.daum.net,2009:kc445.12056615</id>
	    <author>
		    <name>kc445</name>
	    </author>
	    <updated>2009-01-30T16:09:27Z</updated>
	    <published>2009-01-30T16:09:27Z</published>
	    <content type="html">
	    	&lt;P align=center&gt;&lt;FONT face=&quot;Rockwell Extra Bold&quot; color=#660033 size=6&gt;Gas Turbine and Combined-Cycle&lt;BR&gt;Power Plants in South Korea&lt;/FONT&gt; 
&lt;TABLE borderColor=#000080 height=1014 width=&quot;100%&quot; border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=94&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/bugok-2.jpg&quot; width=300 border=1&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=94&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/bundang.jpg&quot; width=300 border=1&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;34%&quot; height=94&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/hyundai-petrochem.jpg&quot; width=300 border=1&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=100&gt;&lt;FONT face=Arial&gt;&lt;FONT size=2&gt;&lt;B&gt;Bugok&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT size=2&gt;Location: Chungcheongbuk-do&lt;BR&gt;Operator: GS EPS Co Ltd&lt;BR&gt;Configuration: Two 495-MW, 2+1 combined-cycle cogeneration blocks with SGT6-4000F gas turbines&lt;/FONT&gt;&lt;BR&gt;&lt;FONT size=2&gt;Fuel: LNG&lt;BR&gt;Operation: 2000-2008&lt;BR&gt;HRSG supplier: Doosan&lt;BR&gt;T/G supplier: Siemens&lt;BR&gt;EPC: KOPEC, LG E&amp;C, Siemens, Kocen&lt;BR&gt;Quick facts: GS EPS is owned by GS Holdings (70%) and Oman Oil Co (30%). GS Holdings was established in Jul 2004 and took over LG Energy Co,in turn&amp;nbsp; founded by LG Corp in 1996 to develop the Bugok plant. It is one of the first IPPs in South Korea. Ground-breaking for the first block was in Dec 1998 and full combined-cycle operation was achieved in Apr 2001. In Nov 2005, construction got underway on a second similar block and this was turned over in Mar 2008 about 1mo ahead of schedule.&lt;/FONT&gt;&lt;/FONT&gt; 
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Siemens&lt;BR&gt;Re-posted 14 Jun 2008&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=100&gt;&lt;FONT face=Arial&gt;&lt;FONT size=2&gt;&lt;B&gt;Bundang&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT size=2&gt;Location: Gyeonggi-do&lt;BR&gt;Operator: &lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT face=Arial size=2&gt;Korean South-East Power Co&lt;/FONT&gt;&lt;FONT face=Arial&gt;&lt;FONT size=2&gt;&lt;BR&gt;Configuration: 600-MW, 5+1 combined-cycle cogeneration power plant with GT11N gas turbines&lt;/FONT&gt;&lt;BR&gt;&lt;FONT size=2&gt;Fuel: LNG, oil&lt;BR&gt;Operation: 1993&lt;BR&gt;HRSG supplier: ABB&lt;BR&gt;T/G supplier: ABB, Mitsui&lt;BR&gt;EPC: KOPEC, Hyundai&lt;BR&gt;Quick facts: Bundang can supply 428 Gcal/hr for the local heating system.&lt;/FONT&gt;&lt;/FONT&gt; 
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Korea South-East Power Co&lt;BR&gt;Posted 1 Aug 2004&lt;/FONT&gt; 
&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;34%&quot; height=100&gt;&lt;FONT face=Arial&gt;&lt;FONT size=2&gt;&lt;B&gt;Daesan-2&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;/FONT&gt;&lt;FONT face=Arial size=2&gt;Location: Chungcheongbuk-do&lt;BR&gt;Operator: Marubeni Corp&lt;BR&gt;Configuration: 507-MW, 4+1 combined-cycle block with W501D5 gas turbines&lt;/FONT&gt;&lt;FONT face=Arial&gt;&lt;BR&gt;&lt;FONT size=2&gt;Fuel: residual oil&lt;BR&gt;Operation: 1998&lt;BR&gt;HRSG supplier: ??&lt;BR&gt;T/G supplier: WH&lt;BR&gt;EPC: Hyundai&lt;BR&gt;Quick facts: The plant was acquired from Hyundai Petrochemical by Sithe Energies in 1999 and later bought out by Marubeni, one of Sithe's two original owners. &lt;/FONT&gt;&lt;/FONT&gt;
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Hyundai Engineering Co Ltd&lt;BR&gt;Posted 22 Aug 2004&lt;/FONT&gt; 
&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=222&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/seochon-cc.jpg&quot; width=300 border=1&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=222&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/kpower.jpg&quot; width=300 border=1&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;34%&quot; height=222&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/poryong-cc.jpg&quot; width=300 border=1&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=83&gt;&lt;B&gt;&lt;FONT face=Arial size=2&gt;Incheon&lt;/FONT&gt;&lt;/B&gt;&lt;FONT face=Arial size=2&gt;&lt;BR&gt;Location: Incheon&lt;BR&gt;Operator: Korea Midland Power Co&lt;BR&gt;Configuration: 500-MW, 2+1 combined-cycle block with SGT6-4000F gas turbines&lt;BR&gt;Fuel: natural gas&lt;BR&gt;Operation: 2006&lt;BR&gt;HRSG supplier: ??&lt;BR&gt;T/G supplier: Siemens&lt;BR&gt;EPC: KOPEC, GS E&amp;C&lt;BR&gt;Quick facts: In early 2003 Siemens PG received the Incheon order. The plant is modeled on Bugok I. At completion, the 58% design thermal efficiency was the highest in the country. 
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of GS E&amp;C&lt;BR&gt;Posted 17 Oct 2006&lt;/FONT&gt;&lt;/P&gt;&lt;/FONT&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=83&gt;&lt;B&gt;&lt;FONT face=Arial size=2&gt;K-Power&lt;/FONT&gt;&lt;/B&gt;&lt;FONT face=Arial&gt;&lt;BR&gt;&lt;FONT size=2&gt;Location: Jeollanam-do&lt;BR&gt;Operator: &lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT face=Arial size=2&gt;K-Power Ltd&lt;/FONT&gt;&lt;FONT face=Arial&gt;&lt;FONT size=2&gt;&lt;BR&gt;Configuration: 2 X 537-MW, 2+1 combined-cycle blocks with 7001FA gas turbines&lt;/FONT&gt;&lt;BR&gt;&lt;FONT size=2&gt;Fuel: LNG&lt;BR&gt;Operation: 2006&lt;BR&gt;HRSG supplier: Nooter&lt;BR&gt;T/G supplier: GE&lt;BR&gt;EPC: Daelim&lt;BR&gt;Quick facts: This is South Korea's first private merchant power plant. K-Power is a 65:35 joint venture of SK Corp and BP.&amp;nbsp; In Aug 2004, the company signed a $2bn, 20yr agreement to buy LNG from the Tangguh field in Indonesia. Baker &amp; McKenzie advised on this transaction.&lt;/FONT&gt;&lt;/FONT&gt; 
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of K-Power&lt;BR&gt;Posted 1 Nov 2006&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;34%&quot; height=83&gt;&lt;FONT face=Arial&gt;&lt;FONT size=2&gt;&lt;B&gt;Poryong CC&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT size=2&gt;Location: Chungcheongnam-do&lt;BR&gt;Operator: &lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT face=Arial size=2&gt;Korean Midland Power Co&lt;/FONT&gt;&lt;FONT face=Arial&gt;&lt;FONT size=2&gt;&lt;BR&gt;Configuration: 4 X 500 MW, 2+1 combined-cycle blocks with GT24A gas turbines&lt;/FONT&gt;&lt;BR&gt;&lt;FONT size=2&gt;Fuel: LNG&lt;BR&gt;Operation: 1997-2000&lt;BR&gt;HRSG supplier: Hanjung&lt;BR&gt;T/G supplier: ABB&lt;BR&gt;EPC: ABB, Hyundai&lt;/FONT&gt;&lt;/FONT&gt; 
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Hyundai Engineering Co Ltd&lt;BR&gt;Posted 5 Aug 2004&lt;/FONT&gt; 
&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=83&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/Pusan-cc.jpg&quot; width=300 border=1&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=83&gt;&amp;nbsp;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;34%&quot; height=83&gt;&lt;IMG height=220 src=&quot;http://www.industcards.com/Yulchon.jpg&quot; width=300 border=1&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=83&gt;&lt;FONT face=Arial&gt;&lt;FONT size=2&gt;&lt;B&gt;Pusan CC&lt;/B&gt;&lt;/FONT&gt;&lt;BR&gt;&lt;FONT size=2&gt;Location: Busan-gwangyoksi&lt;BR&gt;Operator: &lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT face=Arial size=2&gt;Korean Southern Power Co&lt;/FONT&gt;&lt;FONT face=Arial&gt;&lt;FONT size=2&gt;&lt;BR&gt;Configuration: 4 X 450 MW, 2+1 combined-cycle blocks with 7001FA gas turbines&lt;/FONT&gt;&lt;BR&gt;&lt;FONT size=2&gt;Fuel: LNG&lt;BR&gt;Operation: 2000-2004&lt;BR&gt;HRSG supplier: Doosan&lt;BR&gt;T/G supplier: GE&lt;/FONT&gt;&lt;/FONT&gt; 
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of Power&lt;BR&gt;Posted 14 Aug 2004&lt;/FONT&gt; 
&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;33%&quot; height=83&gt;&amp;nbsp;&lt;/TD&gt;
&lt;TD vAlign=center align=middle width=&quot;34%&quot; height=83&gt;&lt;B&gt;&lt;FONT face=Arial size=2&gt;Yulchon&lt;/FONT&gt;&lt;/B&gt;&lt;FONT face=Arial size=2&gt;&lt;BR&gt;Location: Chollabuk-do&lt;BR&gt;Operator: Meiya Power Co&lt;BR&gt;Configuration: 500-MW, 2+1 combined-cycle block with W501F gas turbines&lt;BR&gt;Fuel: natural gas&lt;BR&gt;Operation: 2004-2005&lt;BR&gt;HRSG supplier: Doosan (CMI)&lt;BR&gt;T/G supplier: Siemens&lt;BR&gt;EPC: Hyundai&lt;BR&gt;Quick facts: In 1996, Hyundai Energy secured a generator license and a PPA with Kepco for this $300mn plant at Yulchon Industrial Complex and then shopped the project to private power companies. In Dec 2001, Mirant Corp agreed to acquire Hyundai Energy. A year later, Meiya Power Co Ltd announced the acquisition of 100% of Mirant Yulchon Generation Co Ltd and project financing was completed in Jan 2003. The key component was a limited recourse loan of $220mn from Korea Development Bank. 
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Photograph courtesy of CMI HRS&lt;BR&gt;Posted 9 Mar 2006&lt;/FONT&gt;&lt;/P&gt;&lt;/FONT&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=center align=middle width=&quot;100%&quot; colSpan=3 height=83&gt;&lt;IMG height=100 src=&quot;http://www.industcards.com/KOREA-S.jpg&quot; width=150 border=1&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;FONT face=Arial size=1&gt;Abbreviations:&amp;nbsp; CC = combined-cycle, GE = General Electric , GT = gas turbine, HRSG = heat recovery steam generator, IPP = independent power project, KOPEC = Korea Power Engineering Corp, MHI = Mitsubishi Heavy Industries, PPA = power purchase agreement, T/G = turbine generator&lt;/FONT&gt;&lt;/P&gt;
	    </content>